IBM Flex System p24L
|
IBM Flex System p260
|
IBM Flex System p270
|
IBM Flex System p460
|
Form factor
|
Flex System standard node
|
Flex System standard node
|
Flex System standard node
|
Flex System double-wide node
|
Processor cores
|
8 or 16 64-bit POWER7 cores with
AltiVec SIMD and Hardware Decimal Floating-Point acceleration Configuration
Options:
|
2, 4, 8 or 16 cores, POWER7+, 64-bit
processors with VSX, Memory Expansion acceleration and Encryption
acceleration
|
24 cores, POWER7+, 64-bit processors
with VSX, Memory Expansion acceleration and Encryption acceleration
|
16 or 32 cores, POWER7 64-bit processors
with AltiVec SIMD and Hardware Decimal Floating-Point acceleration
|
6-core 3.7 GHz or
|
Configuration Options:
|
|
16 or 32 cores, POWER7+, 64-bit
processors with VSX, Memory Expansion acceleration and Encryption
acceleration
|
|
8-core 3.2 GHz or
|
2-core 4.0 GHz
|
Configuration Options:
|
Configuration Options:
|
|
8-core 3.5 GHz
|
4-core 4.0 GHz
|
12 x 3.1 GHz POWER7+ processor cores
or
|
4-core 3.3 GHz or 4.0 GHz
|
|
|
8-core 3.6 GHz
|
12 x 3.4 GHz POWER7+ processor cores
|
8-core 3.2 GHz or 3.6 GHz
|
|
|
8-core 4.1 GHz
|
|
8-core 3.5 GHz or 4.1 GHz
|
|
|
256 KB per processor core
|
|
|
|
Level 2 (L2) cache
|
256 KB per processor core
|
256 KB per processor core
|
256 KB per processor core
|
256 KB per processor core
|
Level 3 (L3) cache
|
4 MB per processor core
|
10 MB per processor core on P7+
offerings
|
10 MB per processor core
|
4 MB per processor core on 3.3, 3.2
and 3.5 GHz P7 offerings
|
10 MB per processor core on 3.6, 4.0
and 4.1 GHz P7+ offerings
|
||||
Memory (min/max)
|
8 GB up to 512 GB, 16 DIMM slots, ECC
IBM Chipkill DDR3 SDRAM running at 1066 MHz
|
8 GB up to 512 GB, 16 DIMM slots, ECC
IBM Chipkill DDR3 SDRAM running at 1066 MHz plus
|
8 GB up to 512 GB, 16 DIMM slots, ECC
IBM Chipkill DDR3 SDRAM running at 1066 MHz plus
|
16 GB up to 1 TB node, 32 DIMM slots,
ECC IBM Chipkill DDR3 SDRAM running at 1066 MHz plus
|
Active Memory Expansion with hardware
assist
|
Active Memory Expansion with hardware
assist
|
Active Memory Expansion with hardware
assist
|
||
Internal disk storage
|
Up to two 2.5” Hard Disks or two
1.8” Solid State Drives
|
Up to two 2.5-inch Hard Disks or two
1.8-inch Solid State Drives
|
Up to two 2.5-inch Hard Disks or two
1.8-inch Solid State Drives
|
Up to two 2.5-inch Hard Disks or two
1.8-inch Solid State Drives
|
Networking/Expansion
|
Two PCI-E Expansion Slots
|
Two PCIe Expansion Slots
|
Two PCIe Expansion Slots
|
Four PCIe Expansion Slots
|
One ETE adapter card slot (provides
dedicated Dual VIOS on internal drives with optional adapter)
|
||||
Systems management
|
Integrated systems management
processor, light path diagnostics, Predictive Failure Analysis, Cluster
Systems Management (CSM), Serial Over LAN, IPMI compliant
|
Integrated systems management
processor, light path diagnostics, Predictive Failure Analysis, Cluster
Systems Management (CSM), Serial Over LAN, IPMI compliant
|
Integrated systems management
processor, light path diagnostics, Predictive Failure Analysis, Cluster
Systems Management (CSM), Serial Over LAN, IPMI compliant
|
Integrated systems management
processor, light path diagnostics, Predictive Failure Analysis, CSM, Serial
Over LAN, IPMI compliant
|
RAS features
|
Chassis redundant/hot plug Power &
Cooling
|
Chassis redundant/hot-plug power and
cooling
|
Chassis redundant/hot-plug power and
cooling
|
Chassis redundant/hot-plug power and
cooling
|
Front Panel and FRU/CRU LEDs
|
Front Panel and FRU/CRU LEDs
|
Front Panel and FRU/CRU LEDs
|
Front Panel and FRU/CRU LEDs
|
|
Concurrent code update
|
Concurrent code update and Processor
deallocation
|
Concurrent code update and Processor
deallocation
|
Concurrent code update and Processor
deallocation
|
|
Processor deallocation
|
Compute node hot plug and Dual VIOS
support
|
Compute node hot plug and Dual VIOS
support
|
Compute Node hot plug and Dual VIOS
support
|
|
ITE hot plug
|
Dual AC Power Supply
|
Dual AC Power Supply
|
Dual AC Power Supply
|
|
Dual AC Power Supply
|
Auto reboot on power loss
|
Auto reboot on power loss
|
Auto reboot on power loss
|
|
Auto reboot on power loss
|
Internal and chassis-external
temperature monitors
|
Internal and chassis-external
temperature monitors
|
Internal and chassis-external
temperature monitors
|
|
Internal and chassis-external
temperature monitors
|
System management alerts
|
System management alerts
|
System management alerts
|
|
64B Marking ECC code supporting x8 IS
DDR3 DIMMs
|
IBM Chipkill ECC detection and
correction
|
IBM Chipkill ECC detection and
correction
|
IBM Chipkill ECC detection and
correction
|
|
System mgmt alerts
|
|
|
|
|
IBM Chipkill ECC detection and
correction
|
|
|
|
|
Operating systems
|
RHEL 5.7, 6.2
|
AIX 6.1, AIX 7.1
|
AIX 6.1, AIX 7.1
|
AIX 6.1, AIX 7.1
|
SLES11 SP2
|
IBM i 6.1 and 7.1
|
IBM i 6.1, IBM i 7.1
|
IBM i 6.1 and 7.1
|
|
|
RHEL 5.7, 6.2; SLES11 SP2
|
RHEL 6.4, SLES11 SP2
|
RHEL 5.7, 6.2; SLES11 SP2
|
|
Energy management
|
EnergyScale™ energy management
|
EnergyScale™ energy management
|
EnergyScale™ energy management
|
EnergyScale energy management
|